The sensor reads a cone, not a point. Centred on the detection window and perpendicular to it, the usable area is a circle:
l At 100 mm working distance: readings stay within 10 % across a Ø100 mm circle on the target surface.
l At 10 mm working distance: the same 10 % band covers ±50 mm horizontally from the axis.
Anything outside that circle is still detected — it is simply not covered by the accuracy specification above. Size the mounting position so the area you care about sits inside the circle, and put the sensor on the axis of the part rather than at one corner of it.
Three geometry rules that decide whether the number is right
1. The window must be parallel to the surface. The AP-YV3304 cannot perform tilted detection. A window that is not parallel to the charged surface returns a reading that either fails or is shifted by an amount you cannot correct afterwards. Use a bracket that holds the window flat to the face you are measuring.
2. Nothing in between. No shield, no frame, no guard, no insulating coating inside the detection path. Any obstruction between the window and the object changes the field the sensor sees.
3. Mount on metal, not on plastic. The sensor body must be reliably grounded through the fixture. The Ø5 mm stainless mounting rod, where used, must not carry an insulating coating.
The unit is held by M3 screws through the mounting holes in the housing. Vertical and horizontal variants put those holes on different faces, which is the only difference that matters when you are working inside a machine frame.