Model
|
AP-DB1223
|
Input voltage
|
DC 24V
|
Power
|
< 5.5W
|
Working voltage
|
±10KV-15KV
|
Ion emission
|
Pulse DC
|
Emitter electrode
|
Si
|
Output frequency
|
0.01,0.03,0.05,0.07,0.1,0.3,0.5,0.7,1,3,5Hz;
ex-work setting:5Hz,parameters can be adjusted by coding switch or remote control. The ion balance has been calibrated at the factory whichcan be adjusted again with a charge plate tester by selecting the appropriate operating frequency according to the on-site usage.
|
Duty ratio
|
5%—95%(Parameters can be adjusted by remote control)
|
Ozone thickness
|
< 0.1ppm(50mm away from the emitter electrode )
|
Alarm indicator
|
Green light—Normal work, Red light—Abnormal high voltage, Blue light—Debugging/cleaning indication RJ45 port indicator: Green light—Power-on indication, Orange light—Flashing with working frequency
|
Status monitoring
|
RS485(115200bps,8,1,n,n)≥ 20ms
|
Collector open circuit:< 50V,100mA
|
Working temperature
|
0℃ -50℃
|
Working humidity
|
< 70%
|
Dimensions
|
L*W*H:{750,1150,1550…→ 3150}*36*68mm
|
Bar material
|
Flame retardant PVC、ABS
|
Packaging accessories
|
180°rotatable mounting bracket,M5-12*12*4 square nut
|
Power adapter
|
GRT-240200:DC24V 2A,dual network port output,123*61*40.5mm(L*W*H)
|
Power cord
|
2.5m
|
Warranty
|
1Year
|
Certification
|
CE
|